Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. The instrument have one complete parameter set. Only wire the other instruments SG terminal. Yokogawa TC10 Manual Download for 1 TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. Do not run input wires together with power cables. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required. Notes: 1. IM 05C01E81-11EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10-L is a panel mounting, Class II instrument. Moreover, provide indication that the. Yes, if the input type is voltage or current. Safety, Protection and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. Model: TC10-L Quick Guide . future reference. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Please, provide a T type 1A, 250 V fuse externally. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. Download Manual of YOKOGAWA TC 10-L Controller for Free or View it Online on All-Guides.com. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. Model: digitalview ALR-1400, digitalview 417100041-3. It has been de- signed with compliance to the European Directives. SSR outputs are not isolated. Category: Controller. At this point the instrument restarts as for a new power ON. Looking for more information on our people, technology and solutions? The ambient temperature is in accordance with the operative, 6. 4 2.4 SERIAL INTERFACE. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? View online (36 pages) or download PDF (3 MB) YOKOGAWA TC10 User manual TC10 PDF manual download and more YOKOGAWA online manuals The TC10 supports easy configuration with codes for quick start-up. user must refer to the Engineering manual for special instructions. This manual describes how to use UT55A/UT52A functions other than UT55A/UT52A's communication function and ladder sequence function . View available part numbers. The UT32A-D is a compact digital indicating controller with selectable 2-loop control. IM 05C01E81-01EN 1 Edition Oct. 2014 st Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns Declaration of conformity and Manual retrieval TC10 is a panel mounting, Class II instrument. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. The TC10 supports easy configuration with codes for quick start-up. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. SSc allows the scaling of the analog input to set the minimum displayed/measured value. requirements of the area in which the instrument is being installed. Cold junction accuracy: 0.04C/C after a warm-up of 20 minutes. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. Is there a controller to which I can connect a 2-wire Pt1000 sensor? The UT75A also support open networks such as Ethernet communication. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. of use, service life and misuse are not covered by this warranty. The shallow depth of the controller helps to save instrument panel space. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. The Yokogawa TC10 is a compact, all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. exposed terminals and wiring on the back. When you do this, the upper limit range of 1000C becomes 999.9C. The following symbol is, This manual is an essential part of the product; keep it in a safe place for. 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. all phases of operation, service and repair of this instrument. ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. connected to the low-voltage installation. View and Download Yokogawa TC10-L instruction manual online. The conguration procedure allows to take advantage of all instrument features. What is the I/O response time of the TC10? Nadcap AMS2750F - What's New and How to Comply? Assign OP4 to the control output operation. The TC10 supports easy configuration for quick start-up, and itsPID allows for overshoot andundershoot control, so the end user can maintain a direct and constant temperature or accurate flow. When installing the TC10, what is the depth in millimeters from the surface of the panel? There's no SG terminal for wiring RS485 communication on the TC1. 1. No. TC10-L is capable of a retransmission output and up to two alarm outputs. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. (100 to 240 VAC), Insulation voltage: 3000 V AC for 1 minute between primary and secondary terminals, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Serial Communication (optional): RS-485 MODBUS. Only wire the other instruments SG terminal. It has been designed with compliance to the European Directives. condensation); 5. (63% response when the input changes from 10% 90%). In other words the upper display will show: ]INP. There are no water or other uids (i.e. 2. The shallow depth of the controller helps to save instrument panel space. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. There is no parameter for specifying the output direction. The upper display will show PASS while the lower display shows 0; 2.Using and buttons set the value -481; 4.The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. Yokogawa TC10-L Limit Controller Starting at $329.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Some models in stock. Fsc allows the scaling of the analog input to set the maximum displayed/measured value. If the password is correct the display will show the acronym of the rst parameter group preceded by the symbol: ]. Push button for more than 3 seconds, the instrument will come back to the standard display. Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration.